Download the S-PLUS Program for the Analysis of Accelerated Titration Designs

Download File

Download the SPlus Program

Instructions to Run the Downloaded File

Software requirements: S-PLUS 3.3 or higher (under MS Windows). Before running the program, load the functions by typing source('...../ph1atd').  To run the program, type ph1atd( 'inputfile' , 'doselist' ) at the S-PLUS prompt,  where the "inputfile" is an ASCII file which contains the patient data in the following format, one record(line) per course:

  • Column 1: patient number
  • Column 2: course number
  • Column 3: dose
  • Column 4: toxicity

(Records should be ordered by patient and course number) and "doselist" is an ASCII file which contains all the doses planned to be used in the trial listed in a single column in ascending order.

Program Output

  • Maximum likelihood estimates of the model parameters
  • Confidence intervals for parameters with non-zero MLE, both MLE and CI are sent to the screen and file "ph1atd.out"
  • Graph of probabilities of grade2+, 3+ and 4+ toxicities (for the first course) averaged over the population of patients. (the graph is stored in file "ph1atd1.wmf")
  • Graphs of probabilities of grade2+, 3+ and 4+ toxicities (for the first course) for the patients with beta equal to MLE-SD, MLE and MLE+SD. (the graphs are stored in file "ph1atd2.wmf")

Note: If the MLE of sigma beta is 0 these graphs are not produced.

If you would like to reproduce some or all of this content, see Reuse of NCI Information for guidance about copyright and permissions. In the case of permitted digital reproduction, please credit the National Cancer Institute as the source and link to the original NCI product using the original product's title; e.g., “Download the S-PLUS Program for the Analysis of Accelerated Titration Designs was originally published by the National Cancer Institute.”